background image

- 6 -

Selecting the "Day off" operating mode

1. Press the 

PROG

 button and turn the adjustment dial 

to the left until 

day off

 is displayed.

2. Confirm the selected operating mode with the 

 OK 

 

button.

Days 

flashes.

3. Use the adjustment dial to set the desired number of 

days and confirm with 

 OK 

.

The selected operating mode is displayed.

i

•  The procedure of creating the time program for a 

day off is described in Section 8.

•  When the number of days for holiday/day off is 

entered, the current day counts as the first day.

•  An overview of the program structure is shown on 

the last page of these instructions.

7. Programming – temperatures  

For the time program three preset temperatures which 
can be assigned to the switching points in the time 
program are possible:
•  Comfort temperature 1  

  Factory setting 20 °C

•  Comfort temperature 2  

  Factory setting 22 °C

•  Conserve temperature  

 

Factory setting 16 °C

Setting the temperatures

1. Press the 

PROG

 button. 

comfort 1 

is displayed.

2. Press the 

 OK 

 button, use the adjustment dial to set 

the Comfort temperature 1 and confirm with 

 OK 

.

saved

 is displayed briefly and then again 

comfort

 

1

.

3. Turn the adjustment dial clockwise until the next 

temperature is displayed.

4. Repeat Steps 2 and 3 for the Comfort temperature 2 

and the Conserve temperature.

5. Use the 

AUTO

 button to terminate programming.

i

The three preset temperatures (Comfort 
temperature 1, 2 and Conserve temperature) can be 
changed at any time.

i

•  During programming the 

PROG

 button can be 

used to return to the next level up.

•  You can abort programming at any time by using 

the 

AUTO

 button.

i

An overview of the program structure is shown on the 
last page of these instructions.

8. Programming – time program

Planning the time program

You can specify up to 6 switching points per day.
The following has to be assigned to each switching 
point:
•  One of the three preset temperatures (Comfort 

temperature 1, 2 and Conserve temperature). 

•  Beginning of the Heating/Conserve period
•  End of the Heating/Conserve period

Example

2

3

4

5

Comfort 1

Conserve

Comfort 2

Conserve

Heating

Heating

Heating

Switching points

The example shows the following time program:

Switc

hing 

point time

temperature

1

6:00 – 9:00

 

20 °C (Comfort temperature 1)

2

9:00 – 12:00

 

16 °C (Conserve temperature)

3

12:00 – 14:00

 

20 °C (Comfort temperature 1)

4

14:00 – 17:00

 

16 °C (Conserve temperature)

5

17:00 – 22:00

 

22 °C (Comfort temperature 2)

6

22:00 – 6:00

 

16 °C (Conserve temperature)

i

An overview of the program structure is shown on the 
last page of these instructions.

Week program

You can adjust the time program to your personal weekly 
schedule. You have the following options to this purpose:
•  Separate time programs for weekdays (Mo – Fr) and 

weekend (Sa – Su)

•  One time program for all days of the week (Mo – Su)
•  A different time program for each day of the week 

(Mo, Tu, We, Th, Fr, Sa, Su)

i

We recommend that you record your time program 
before beginning programming.

Summary of Contents for homexpert Rondostat COMFORT+ HR30

Page 1: ...Day off can easily be activated Parameters can be set individually see Section 9 Energy saving functions With the window function an open window is recognised and the radiator valve closed In ECO mode the room temperature is decreased by 3 C Optimised heating or lowering of the room temperature Caution Danger of malfunctions f f Use the radiator controller only in accordance with these operating i...

Page 2: ...xplosion hazard f f Non rechargeable batteries f f Never short circuit batteries or throw them into fire f f Dispose of used batteries ecologically Setting the time and date 1 When hour is displayed use the adjustment dial to set the current hour and confirm with OK minute is displayed 2 Use the adjustment dial to set the current minute and confirm with OK year is displayed 3 Use the adjustment di...

Page 3: ... radiator valve or the adapter and tighten by hand without tools Mounting the radiator controller 1 3 2 1 Ensure that the slide at the radiator controller is in the open position 2 Push the radiator controller onto the valve baseplate so that the geer teeth catch and are no longer visible 3 Lock the radiator controller in the end position To do so slide the slide towards the The radiator controlle...

Page 4: ... Programming Back to next level up 7 Adjustment dial Change settings 8 Button AUTO ECO MANU Change between automatic ECO and manual mode In programming mode Terminate without storing 9 Battery status 10 Operation lock 11 Symbol for Comfort temperature 1 Comfort temperature 2 Conserve temperature Battery display Battery status Meaning Batteries full Batteries half full Batteries have to be replaced...

Page 5: ...t operating mode f fTo activate the manual mode press the button AUTO ECO MANU until manual is displayed The temperature can be adjusted manually using the adjustment dial Manual mode runs until you press the button AUTO ECO MANU again and select a different operating mode 6 Programming Operating modes Overview of the operating modes Party operating mode In this operating mode you can specify a te...

Page 6: ...peratures Comfort temperature 1 2 and Conserve temperature can be changed at any time i During programming the PROG button can be used to return to the next level up You can abort programming at any time by using the AUTO button i An overview of the program structure is shown on the last page of these instructions 8 Programming Time program Planning the time program You can specify up to 6 switchi...

Page 7: ...nt and confirm with OK saved is displayed briefly Subsequently the temperature as well as the beginning and end of the switching point are displayed 5 For the further switching points also select the temperature as well as the beginning and end of the switching point as described in Steps 1 to 5 i A switching point is not saved until the temperature beginning and end have been confirmed with the O...

Page 8: ...ure representation in the display Set programmed temperature setpoint temperature Measured room temperature Par Sett Meaning 10 16 17 30 Upper temperature limit The room temperature cannot be set higher than the specified upper temperature limit HI LIMIT Factory setting 30 C 11 5 6 15 Lower temperature limit The room temperature cannot be set lower than the specified lower temperature limit LOW LI...

Page 9: ...rameter 8 Valve stroke The radiator controller operates with the optimum valve stroke set in the factory If the entire valve stroke is to be used or if the valve does not close completely activate the full stroke mode Parameter 9 Temperature representation in the display In the factory setting the set or programmed temperature Comfort temperature 1 2 or the Conserve temperature is displayed With t...

Page 10: ... mode 10 Further functions Monitoring functions Window function If you open a window causing the temperature to drop the radiator controller closes the radiator valve in order to save energy window is displayed When the temperature rises again but at the latest after the set period factory setting 30 minutes the radiator controller opens the radiator valve again You can also open the radiator valv...

Page 11: ...d Set the slide to the position Emergency operation when batteries are flat 1 Unlock the radiator controller To do so slide the slide at the radiator controller towards the 2 Pull the radiator controller off the valve baseplate 3 Operate the radiator valve by hand using the adjustment dial on the valve baseplate Restoring the factory setting 1 Keep the PROG button pressed for approximately 10 seco...

Page 12: ...rt 1 comfort 2 eco temp program OK OK OK OK OK OK OK OK Hour Days Days Hours Temp Temp Temp Edit time program see below OK OK OK OK OK OK OK Minute Temp Temp OK OK OK Year OK Month OK Day OK Time program program OK turn adjustment dial mo fr sa su mo su mo tu su day off OK OK OK OK OK OK OK OK turn adjustment dial Switch point 1 Switch point 6 New switching point add new Delete a switching point S...

Reviews: