22
Installation and Setup
Figure 2-5
Alarm Connection
The alarm output can be configured to provide normally open or normally closed contacts
(see
to configure the alarm output). Contacts will be rated for
12 V DC @ 0.5 A.
4.
Pull the cables through the back or side entries of the camera skirt, back box and/or
adapter plate (as required), then connect the green connector strip to the camera
assembly. You might have to remove the cover plate for flush mounting the camera.
Connecting Power
WARNING!
The use of a CSA Certified/UL Listed Class 2 power supply is
required to ensure compliance with electrical safety
standards.
Note
Check the power source from the external power supply before applying
power to the camera.
1.
Connect the appropriate power supply for your installation:
•
24 V AC power supply (proceed to
or
•
Power over Ethernet (IEEE 802.3af) 48 V DC power supply
Note
Connect power either from a 24 V AC source or CAT5 Ethernet connector
(PoE). It is not recommended to connect both power sources at the same
time.
Note
If you are using PoE (802.3af), power will automatically be supplied to the
camera through the network cable.