BENDIX/KING
KLN 94
Page 5-22
15599M00.JA
Rev 0, Sept/2000
L.
Potentiometers
Inspect all potentiometers for evidence of damage or loose terminals, cracked in-
sulation or other irregularities.
M.
Resistors, Fixed
Inspect the fixed resistors for cracked, broken, blistered, or charred bodies and
loose, broken, or improperly soldered connections. On chip resistors, be especially
alert for hairline cracks in the body and broken terminations.
N.
RF Coils
Inspect all RF coils for broken leads, loose mountings, and loose, improperly sol-
dered, or broken terminal connections. Check for crushed, scratched, cut or
charred windings. Inspect the windings, leads, terminals and connections for cor-
rosion or physical damage. Check for physical damage to forms and tuning slug
adjustment screws.
O.
Terminal Connections Soldered
(1)
Inspect for cold-soldered or resin joints. These joints present
a porous or dull, rough appearance. Check for strength of
bond using the points of a tool.
(2)
Examine the terminals for excess solder, protrusions from
the joint, pieces adhering to adjacent insulation, and parti-
cles lodged between joints, conductors, or other compo-
nents.
(3)
Inspect for insufficient solder and unsoldered strands of wire
protruding from the conductor at the terminal. Check for in-
sulation that is stripped back too far from the terminal.
(4)
Inspect for corrosion at the terminal.
P.
Transformers
(1)
Inspect for signs of excessive heating, physical damage to
the case, cracked or broken insulation, and other abnormal
conditions.
(2)
Inspect for corroded, poorly soldered, or loose connecting
leads or terminals.
Q.
Wiring/Coaxial Cable
Inspect wiring in chassis for breaks in insulation, conductor breaks, cut or broken
lacing and improper dress in relation to adjacent wiring or chassis.
5.3.2
CLEANING
A.
General
This section contains information to aid in the cleaning of the component parts and
subassemblies of the KLN 94.
WARNING:
GOGGLES ARE TO BE WORN WHEN USING
PRESSURIZED AIR TO BLOW DUST AND
DIRT FROM EQUIPMENT. ALL PERSONNEL
SHOULD BE WARNED AWAY FROM THE IM-
MEDIATE AREA.
Summary of Contents for bendis king KLN 94
Page 2: ...MAINTENANCE MANUAL KLN 94 GPS NAVIGATION SYSTEM ...
Page 11: ...BENDIX KING KLN 94 Rev 0 Sept 2000 15599M00 JWA Page 4 3 FIGURE4 1 KLN 94 UNIT BLOCK DIAGRAM ...
Page 75: ...BENDIX KING KLN 94 Page 5 36 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 80: ...BENDIX KING KLN 94 Rev 0 Sept 2000 15599M00 JWA Page 5 45 FIGURE5 3 KTS 143 TEST FIXTURE ...
Page 89: ...BENDIX KING KLN 94 Page 6 4 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 97: ...BENDIX KING KLN 94 Page 6 16 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 101: ...BENDIX KING KLN 94 Page 6 22 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 104: ...BENDIX KING KLN 94 Page 6 26 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 108: ...BENDIX KING KLN 94 Page 6 32 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 155: ...BENDIX KING KLN 94 Page 6 106 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 159: ...BENDIX KING KLN 94 Page 6 112 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...