BENDIX/KING
KLN 94
Rev 0, Sept/2000
15599M00.JA
Page 4-29
TABLE 4-4 Host Processor Address Map
4.3.4.2.4
Host Flash Memories
The 8Mbit (512k x 16) flash memory (U5010) has a 16 kbyte boot block. This Boot Block is to
ensure that the Boot Software is blocked from any accidental write cycles. For read operations,
MAIN_8M_BOOT_CSn is low, MAIN_RDn is low, and MAIN_WRn is high because of decoding
logic of U5029 and U5041.
During program and erasure, a BDM adapter is connected to J5100. A VPP of +5VDC will be sup-
plied to the Flash VPP when HW_PGM_EN is pulled high by the U5029 PLD. Aternatively, both
the Enter and Cursor keys can be depressed and Program code can be loaded via the Data Load-
er RS-232 interface. Memory contents of U5010 can then be altered.
4.3.4.2.5
Host Non-Volatile Memory
The Host side of MAIN Board contains one 512kbyte (512k x 8) of non-volatile RAM. The non-
volatile RAM U5024 retains its data by applying the battery voltage (VCC_BAT) connected to pin
32 through U5002 pin 2. This will also hold MAIN_SRAM_CSn high to avoid any spurious chip
selects in the power down cycle when the unit is turned off. When powered on, +5V will provide
the required supply voltage to the RAM through U5002. MAIN_SRAM_CS_INn at pin 13 of U5002
controls MAIN_SRAM_CSn.
4.3.4.2.6
Database Interface
The maximum capacity of the Database Flash Memory Chip (U5009) is 4MBytes and is divided
into banks of 64kbyte. To select each of the banks, 6 bank select lines BS(5:0) are decoded with
U5023 using DISCRETE_CS2n, MAIN_DATA_BUS(15:0) and MAIN_WRn.
The MAIN_DB_CSn is used to enable each 64K bank. To support bank crossover, another chip
select line, DBXOVER_CSn (CS2*), is used to address the 2K memory segment following a given
bank. A 6-bit adder in the U5023 PLD implements the crossover. Note that the adding occurs
without any extra programming since the microprocessor’s CS2* chip select will automatically ac-
tivate once the 64kbyte address is exceeded.
uP Chip Select
Designation
Size
Space
Data
Size,
bits
CSBOOT* ROM_CSn
512K
00000-7FFFF
16
FC1_CS4*
XROM_CSn
256K
80000-BFFFF
16
BG_CS1*
DB_CSn
64K
C0000-CFFFF
8
BGACK_CS2*
DBXOVER_CSn
2K
D0000-D07FF
8
FC2_CS5*
SRAM1_CSn
62K
D0800-DFFFF
8
A20_CS7*
SRAM2_CSn
112K
E0000-FBFFF
8
A22_CS9*
PERI_CSn
16K
FC000-FFFFF
8
A19_CS6*
DPRAM_CSn
2K
FC000-FC7FF
8
BR_CS0*
DUARTn
2K
FC800-FC80F
FC810
FC811-FCFFF
8
A23_CS10*
DISCRETE_CSn
2K
FD000
FD001
FD002-FD7FF
8
FC0_CS3*
Not used
2K
FD800-FDFFF
8
A21_CS8*
Not used
8K
FE000-FFFFF
8
Summary of Contents for bendis king KLN 94
Page 2: ...MAINTENANCE MANUAL KLN 94 GPS NAVIGATION SYSTEM ...
Page 11: ...BENDIX KING KLN 94 Rev 0 Sept 2000 15599M00 JWA Page 4 3 FIGURE4 1 KLN 94 UNIT BLOCK DIAGRAM ...
Page 75: ...BENDIX KING KLN 94 Page 5 36 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 80: ...BENDIX KING KLN 94 Rev 0 Sept 2000 15599M00 JWA Page 5 45 FIGURE5 3 KTS 143 TEST FIXTURE ...
Page 89: ...BENDIX KING KLN 94 Page 6 4 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 97: ...BENDIX KING KLN 94 Page 6 16 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 101: ...BENDIX KING KLN 94 Page 6 22 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 104: ...BENDIX KING KLN 94 Page 6 26 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 108: ...BENDIX KING KLN 94 Page 6 32 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 155: ...BENDIX KING KLN 94 Page 6 106 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...
Page 159: ...BENDIX KING KLN 94 Page 6 112 15599M00 JA Rev 0 Sept 2000 THIS PAGE IS RESERVED ...