Compatible 5800 Series Transmitters Table (continued)
Model Product
Input
Type
Description
5816TEMP
Low-Temp. Sensor
RF
Transmits a fault condition when temperature drops below 45°F.
5817 Multi-Point
Universal
Transmitter
RF
Has three unique input (loop) codes: one for a “Primary” contact
loop with programmable options; the others for two “auxiliary”
closed circuit contact loops.
5818 Recessed
Transmitter
RF
•
Reed switch magnetic contact sensor; easily hidden in the frame
and edge of a door or window.
•
Has a single unique input (loop) code.
5819 Shock
Processor
Transmitter
RF
•
Connects to externally mounted inertia-type shock detector (not
supplied).
•
Has built-in tampered cover switch.
•
Has 3 unique input (loop) codes:
Loop 1: Terminals for a wired, N.C. sensor loop.
Loop 2: For a closed circuit contact loop using the built-in reed
switch in conjunction with a magnet.
Loop 3: Terminals for a wired, closed circuit contact loop.
5819WHS
5819BRS
Shock Processor
Transmitter
RF
•
Has built-in shock sensor.
•
Has built-in tampered cover switch.
•
Has 3 unique input (loop) codes:
Loop 1: Built-in shock sensor loop wired to TB1 (normally closed).
Loop 2: For a closed circuit contact loop using the built-in reed
switch in conjunction with a magnet.
Loop 3: Externally wired, closed circuit loop connected to TB2.
5827
Wireless Keypad
Uses House
ID only
•
Can be used to turn the burglary protection on and off.
•
Features the same built-in panic functions as wired keypads.
•
The keypad is identified as zone “00” on wired keypads when it
transmits with a low battery.
5827BD Wireless
Two-Way
Keypad
Uses House
ID only
•
Requires 5800TM Transmitter Module.
•
Operates the system similarly to wired keypads, including panics.
•
Can indicate system status via its 3 LEDs and sounder.
•
Includes 3 panic keys.
5849
5852
Glassbreak Detector
RF
•
House ID must also be set.
•
5849 requires both sound and shock of breaking glass to cause
alarm to be transmitted.
•
5852 uses intelligent acoustic processing.
5890
5890PI
PR Detector
RF or RM
Dual-element passive infrared detector/transmitter with built-in
selectable pulse count.
Note: There is a 3-minute lockout between fault transmissions to
conserve battery life.
5899
Magnets
Package of 4 magnets for use with 5816, 5817, and 5819WHS
transmitters.