Miscellaneous System Fields
*173
RF REPORTING OPTIONS
0 = none
1 = RF Tamper reports during disarm
2 = RF keyfobs send low battery
3 = RF Tamper reports during disarm and
RF keyfobs send low battery
Select desired option.
*175
Tamper Options
Entry 1: 0 = standard tamper detection
1 = detect tamper from bypassed
zones
2 = detect tamper when in Test
mode
3 = detect tamper both when in Test
mode and from bypassed zones
Entry 2: 0 = all users can clear a tamper**
1 = only the installer can clear a
tamper
Select desired options.
Standard Tamper Detection (entry 1 option 0): The system normally
detects tamper faults from devices equipped with tamper switches
(for cover removal and/or wall removal) while the system is armed or
disarmed. Tamper faults are ignored when a zone is bypassed or
when the system is in Test mode unless entry 1 options 1, 2, or 3 are
selected. Tamper display is as follows:
Disarmed:
TAMPER 1xx (or zz)
where 1xx = ECP device address
zz = zone number of faulted device.
Armed:
TMPR_ARMD
** Must be “0” if field *25 entry 2 is set for 1 or 2, otherwise, only the
installer will be able to disarm the system and clear tamper displays.
*176
Siren Options
Entry 1: 0 = external siren
1 = self-activated external siren
Entry 2: 0 = disable siren delay
1 = external siren delay and dialer
delay during entry delay period
when armed AWAY
2 = external siren and dialer delayed
15 seconds when armed STAY
mode
Select desired options.
Entry 1:
If entry 1 is not set to an external siren (option 0 or 1), then
the second entry is ignored.
Entry 2:
Option 1 – When entry delay is active (ex. reentering
premises while armed AWAY) and an instant zone is faulted, the
external siren is delayed 30 seconds and the dialer report is delayed
30 seconds, unless field *50 is set for a greater delay (the 30-second
dialer delay supersedes values less than 30 seconds set in field *50).
Option 2 – When armed STAY and an instant zone is faulted, the
external siren and dialer are delayed 15 seconds (keypad sounds
immediately).
*177
Device Duration 1, 2
Duration 1 – Device Action 5 Timer
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
#+13 = 10 min
2 = 45 secs
8 = 4 min
#+14 = 12 min
3 = 60 secs
9 = 5 min
#+15 = 15 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
Duration 2 – Device Action 6 Timer
1 – 7 = 1 to 7 days
These entries set the duration for output action options 5 (duration
1) and 6 (duration 2) programmed in
∗
80 Output Function
Programming.
Duration 2 can be used as a strobe timer.
*178
RF Supervision / RF Jam Option
0 = RF supervision and RF jam detection
reporting
1 = Report RF supervision failure as tamper
alarm when armed
2 = Report RF Jam as tamper alarm when
armed
3 = Report RF Jam and RF supervision
failure as tamper alarm when armed
NOTES:
RF Jam must be enabled in field
*22 in order for
any
RF reporting to be
enabled in this field.
Alarm restore reports must be enabled
(field *70) in order for RF Supervision/RF
Jam alarm restores to be reported.
Trouble reports and trouble restore reports
must be enabled (fields *60, *71) in order
for RF supervision/RF jam trouble
conditions and restores to be reported.
Select desired option. See field *22 for related options.
Entry 0: RF jam conditions report as Trouble zone 90 (Contact ID
code 344, RF Rcvr Jam Detect) plus a zone trouble report
for each RF zone in the system (CID code 383, Trouble
Sensor Tamper) when the system is armed or disarmed.
Keypads display Tamper zz (zz = zones) and Tamper 90
(fixed-word) or RECEIVER JAM (alpha).
RF supervision failures report as zone troubles (CID code
381, RF Sensor Super.) when the system is armed or
disarmed. Keypads display CHECK zz (zz = zone).
Entry 1: Same as entry 0 except RF supervision failures report as
zone alarms (CID code 144, Alarm Sensor Tamper) when
the system is armed; keypads display ALARM zz.
Entry 2: Same as entry 0 except RF jam conditions report as zone
alarms (Contact ID code 144, Alarm Sensor Tamper) when
the system is armed; keypads display ALARM zz.
Entry 3: Same as entry 0 when disarmed, but when system armed,
both RF jam conditions and RF supervision failures report as
zones alarms (Contact ID code 144, Alarm Sensor Tamper)
Installation Instructions
4-10
Summary of Contents for ADEMCO VISTA-48A
Page 4: ......
Page 28: ...Installation Instructions 3 8 ...
Page 60: ...Installation Instructions 5 20 ...
Page 75: ... NOTES 8 5 ...