FIELD
TITLE and DATA ENTRIES
EXPLANATION
*27
Powerline Carrier Device (X-10)
House ID
0 = A
6 = G
# + 11 = L
1 = B
7 = H
# + 12 = M
2 = C
8 = I
# + 13 = N
3 = D
9 = J
# + 14 = O
4 = E
# + 10 = K
# + 15 = P
5 = F
Powerline Carrier devices require a House ID, identified in this field.
Program Powerline Carrier devices in interactive modes
∗
79, *80 and
*81.
*29
ECP Contact ID Output for ACM
0 = not used
1 = use Contact ID output on ECP
If selected, all messages programmed to go to the primary telephone
line receiver will also be sent to the connected Alternative
Communication Media (ACM), such as a 7845i Internet/Intranet
Communicator or AI4164RS/AI4164ETH Eureka Network Interface
(sent in Contact ID format). The data line is supervised as well as
certain functions in a long range radio. If communication is lost or a
trouble develops, an attempt will be made to send a message via both
ACM and telephone to the central station.
Program the ACM for device address 3.
*30
Make Partition 3 a Common Area
Partition
0 = no (must be 0 if system uses zone type
82 - Blockschloss)
1 = yes, make partition 3 a common area
partition
If selected, partition 3 functions as a common area partition, rather
than as an independent partition.
Scheduling Note: If partition 3 is set as a common partition, the
scheduling events Auto Stay Arm (event 04) and Auto Arm (event 5)
cannot be used. To use these scheduling features, *30 must be 0.
Zone Sounds & Timing
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*31
Single Alarm Sounding Per Zone
(per armed period)
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming
period for a given zone
Select whether a zone going into alarm should sound more than once
per armed period.
*32
Fire Alarm Sounder Timeout
0 = yes; fire sounder timeout after time
programmed in field
∗
33
1 = no fire sounder timeout; continue
sounding until manually turned off
Select whether fire alarm sounding expires after sounder timeout or
remains until manually turned off.
*33
Siren Timeout
0 = No timeout
4 = 4 min
1 = 1 min
5 = 8 min
2 = 2 min
6 = 16 min
3 = 3 min
This field determines whether the external sounder will shut off
after time allotted, or continue until manually turned off.
*34
Exit Delay
00 - 96 = 0 - 96 seconds
97 = 120 seconds
The system waits the time entered before arming entry/exit zones. If
the entry/exit door is left open after this time expires, an alarm will
occur or the zone will be auto-bypassed, depending on the selection in
field *88. Common area zones use same delay as partition 1.
*35
Entry Delay 1
00 - 96 = 0 - 96 seconds
97 = 120 seconds
98 = 180 seconds
99 = 240 seconds
Upon entering, the system must be disarmed before the time entered
expires, otherwise it sounds an alarm. Common area zones use same
delay as partition 1.
*36
Entry Delay 2
See *35 above for entries.
See *35 for explanation.
*37
Audible Exit Warning
0 = no; 1 = yes
Warning sound consists of slow continuous beeps until last 10 seconds,
then it changes to fast beeps. Sound ends when exit time expires.
Installation Instructions
4-2