*38
Confirmation Of Arming Ding
Entry 1:
0 = no; 1 = yes, 1-second ding
(ding if armed from wired keypad)
Entry 2:
Enter 0-15 from table below.
(ding if armed from keyswitch and/or
RF device)
Entry
Ding at Siren Trigger 2 Output
0 none
none
1 none
250mS
2
none
1 second
3
none
4 seconds
4
250mS
none
5
250mS
250mS
6
250mS
1 second
7
250mS
4 seconds
8
1 second
none
9
1 second
250mS
#+10
1 second
1 second
#+11
1 second
4 seconds
#+12
4 seconds
none
#+13
4 seconds
250mS
#+14
4 seconds
1 second
#+15
4 seconds
4 seconds
Entry 1
for each partition selects whether arming from wired
keypads causes siren ding. Confirmation of arming is an external
sounder “ding” that follows the time selected in entry 2 for “ding at
siren.” Ding occurs when closing reports is sent, or when exit delay
expires.
Entry 2
for each partition selects whether arming from a keyswitch
and/or remote RF devices causes siren ding and/or activates trigger 2
output; also selects siren ding/trigger activation duration (arm = 2
dings of selected duration with 1 second off between; disarm = 1 ding
of selected duration). Ding occurs upon reception of the wireless
arming command.
NOTE:
If using an option that activates trigger 2, trigger 2 must be
dedicated to only this function; do not assign any other functions to
trigger 2.
*39
Power-Up In Previous State
0 = always power-up in a disarmed state
1 = assume the system status prior to
power down
When the system powers up armed, an alarm will occur 1 minute
after arming if a zone is faulted at that time.
Note that if the previous state was armed AWAY or STAY, the
system will not respond to sensor changes for 1 minute, which allows
time for sensors such as PIRs to stabilize.
Dialer Programming (
∗∗∗∗
40 –
∗∗∗∗
50)
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*40
PABX Access Code
Enter up to 6 digits if PABX is needed to
access an outside line. Do not fill unused
spaces.
0–9, # + 11 for ‘
∗
’, # + 12 for ‘#’, # + 13 for a
pause (2 seconds)
To clear entries from field, press
∗
40
∗
. If fewer than 6 digits need to
be entered, exit by pressing [
∗
], which advances to the next field.
Call Waiting:
If the subscriber’s phone service has “call waiting”
(and is not using PABX), enter “*70” (“# + 11”) plus “# + 13” (pause)
as the PABX entry to disable “call waiting” during control panel calls.
If the subscriber does not have “call waiting” and is not using PABX,
make no entry in this field.
*41
Primary Phone No.
Enter up to 30 digits. Do not fill unused
spaces.
0–9, # + 11 for ‘
∗
’, # + 12 for ‘#’, # + 13 for a
pause (2 seconds)
If you enter fewer than 30 digits, exit by pressing [
∗
]. To clear entries
from field, press
∗
41
∗
.
NOTE:
Backup reporting (in which 8 calls are made to the secondary
phone number if no kissoff is received after 8 attempts to the
primary number) is automatic only if there is a secondary phone
number (field
∗
42).
*42
Secondary Phone No.
Enter up to 30 digits.
0–9, # + 11 for “
∗
’, # + 12 for ‘#’, # + 13 for a
pause (2 seconds)
If you enter fewer than 30 digits, exit by pressing [
∗
]. To clear entries
from field, press
∗
42
∗
. See backup reporting note for field
∗
41.
Don’t fill unused spaces.
*43
Part. 1 Primary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press
∗
43
∗
.
*44
Part. 1 Secondary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press
∗
44
∗
.
*45
Part. 2 Primary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press
∗
45
∗
.
*46
Part. 2 Secondary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press
∗
46
∗
.
4-3
Summary of Contents for ADEMCO VISTA-48A