6164 Keypad Expansion Zones
1. Connect each keypad to the control’s keypad
terminals.
If power supervision is required, use the Trigger
Module terminals as described in the
Aux Power
Supervision Connections
paragraph in the
Wiring
to Keypads
section (page 2-3).
2. Using the keypad’s program mode, assign each
keypad a unique keypad address (16-23), and assign
a device address (07-11) from the following chart,
based on the zone numbers being used.
6164 Keypad Addresses
For Zones…Set Keypad to Device Address…
09-12
07
(not available if zone-doubling enabled)
17-20
08
25-28
09
33-36
10
41-44
11
3. Connect sensors to the keypad’s zone terminals.
4. If using the keypad relay, connect the desired field
wiring to the keypad's relay contact terminals.
See 6164 Keypad Instructions for other mounting,
wiring, and programming information.
Notes
•
Each 6164 keypad supports up to 4 wired
expansion EOLR or double-balanced zones and
one relay output.
•
Use 2000 ohm end-of-line resistors at the end of
loops connected to the 6164 keypads.
•
Enter 6164 keypad program mode by pressing
and holding down both the [1] and [3] keys
within 60 seconds of power up.
•
Enable the keypad addresses using data fields
*191-*196 as required.
•
Program keypad zones using *56 Menu mode.
Keypad zones 1-4 correspond to the respective
groups of zones shown in the chart at left, where
keypad zone 1 is the lowest zone number in each
group.
[-] GROUND (-12V)
G
Z1
Z2
(Z1
&
Z2)
(Z3
&
Z4)
Z4
Z3
2K
2K
2K
2K
TAMPER
CONTACTS
TAMPER
CONTACTS
N.O.
N.C.
DOUBLE BALANCED
CONVENTIONAL
EOLR
6164-005-V2
[Y] DATA IN (<)
[+] +12VDC IN
[G] DATA OUT (>)
OPTIONAL
Y +
N.O.
C.
N.C.
Installation Instructions
2-8
Summary of Contents for ADEMCO VISTA-48A
Page 4: ......
Page 28: ...Installation Instructions 3 8 ...
Page 60: ...Installation Instructions 5 20 ...
Page 75: ... NOTES 8 5 ...