Powerline Carrier Devices
1. Install up to 16 powerline carrier devices (if no relays
are used) according to the instructions included with
each.
2. Connect the Powerline Interface Modulator to the
Trigger Module connector using SA4120XM-1 cable
as shown below.
3. Use Programming Mode to enter the device house ID
in data field*27, and enter the unit code using *79
Output Device menu Mode.
Notes
•
When using Powerline Carrier devices, you must
use a Powerline Carrier Device Modulator. It
supplies signals from the control panel through
the premises AC mains wiring to the Powerline
Carrier devices (which are plugged into AC
outlets). You can then make devices that are
plugged into Powerline Carrier devices perform
various functions in response to commands you
enter at the security system keypads.
7 8
(USE SA4120XM-1CABLE)
SYNC BLK)
COM (VIO)
DATA (BLU)
TO X-10
TRANS.
1 2 3 4 5 6
SUPV
TRIG 1
TRIG 2
( ) VTRIG
( ) AUX
( ) GND
TRIGGER MODULE
+
+
-
NOT USED
V48A-V48E-004-V0
Trigger Module Powerline Interface Connections
Installation Instructions
2-12