Maximum Distances for Video, Data, Power, Contact and UTP Cabling
Note
The terms
shielded
and
unshielded
are interchangable with
screened
and
unscreened
, respectively.
Note
UTP is a general term for all cabling systems used for transmission of
unshielded data and providing connectivity on a network. A UTP cable can
contain multiple pairs of twisted cables. Commonly used for telephone
cabling and 10BaseT and 100BaseT networks.
Installation of cable gauges and distances that are outside the scope of
are undertaken solely at the installer’s risk and responsibility.
Table 1-4
Video, Data, Power, Contact and UTP Cabling
Type
Recommended Cable
Maximum Distance
Video
Coaxial cable - RG59/U
Connector - BNC crimp on
for RG59/U
1000 feet (305 meters)
Data
One shielded twisted pair,
RS485 cable including CAT5
or better
4000 feet (1219 meters)
Power
18 AWG 2-conductor
See gauge chart for each
dome
Contact (Alarm)
20 gauge unshielded twisted
pair
10,000 feet (3048 meters)
Unshielded
Twisted Pair (UTP)
Video
CAT5 or better
1 twisted pair for video
750 feet (229 meters)