ACUIX
TM
ES Installation and Configuration Guide
Document 800-01949 Rev D
43
05/09
Installing In-Ceiling Domes
Note
Each dome requires a 24V AC at 1 A or 12V DC at 1.5A ± 15% power source
when measured at the dome. To maintain 24V AC at 1 A or 12V DC at 1.5A ±
15% at each dome, the proper wire size for the distance and the number of
domes must be determined.
The following explains how to install into a dropped (false) ceiling or a hard ceiling. For
dropped ceiling installations, use a separately ordered ceiling plate (Honeywell part
number 517082-7130). In addition to the other items normally supplied by the installer, the
following may be required:
•
Tape or plastic channel to prevent dust and material from dropping from the ceiling.
•
Safety cable - a 3/32” (approximately 2.4 mm) plastic coated aircraft cable with a
looping sleeve is recommended.
Figure 2-8
In-ceiling Dome Layout
How to Install an In-ceiling Dome for a Dropped or Hard Ceiling
1.
Select a location to install the in-ceiling dome(s).
2.
Prepare the ceiling and/or ceiling tile:
Hard Ceiling
•
Using the mounting template, cut a 7 5/8” (194 mm) diameter hole in the ceiling.
If the ceiling is drywall or plaster, it is recommended to seal the entire perimeter of
the hole with tape or plastic channel to prevent dust and material from
contaminating the camera.
Dropped (False) Ceiling
a.
Remove the ceiling panel at the dome location.
b.
Place the ceiling tile on the dropped ceiling plate (Honeywell part number
517082-7130).
c.
Trim the ceiling tile and press it into the dropped ceiling plate.
Cable can
Lower dome
Turning screws
and wing tabs
Trim ring
Cable can wiring access
hole and clamp
Scan assembly
and housing
Summary of Contents for ACUIX ES
Page 1: ...Document 800 01949 Rev D 05 09 Installation and Configuration Guide ACUIX ES PTZ Analog Dome ...
Page 10: ...10 ...
Page 12: ...12 ...
Page 26: ...26 Introduction to the ACUIX ES PTZ Dome ...
Page 46: ...46 Installing the ACUIX ES ...
Page 70: ...70 Configuring the ACUIX ES ...