ACUIX
TM
ES Installation and Configuration Guide
Document 800-01949 Rev D
39
05/09
Connecting the Optional Contact Input Wiring
Note
The contact cabling should not be terminated until standard operation of the
dome is tested.
The plugs for the 3- and 9-pin connections to the contact inputs are located on the scan
assembly. See
for the location. If contact devices are connected to
the dome, they should not be connected to the contact connector until all dome
functionality has been fully tested. Contact device activations could cause confusion during
the initial testing stages.
for wiring information.
All contact input connections MUST be passive contacts.
Table 2-7
Contact Wiring 3 Pin
Pin
P2 (3 pin)
1
Contact input 1
2
Contact input common
3
Contact input 2
Table 2-8
UTP and Contact Wiring 9 Pin (Optional)
Pin
P3 (9 pin)
1
UTP + signal
2
UTP - signal
3
Contact input 3
4
Contact input 4
5
Contact input 5
6
Contact input 6
7
Contact input 7
8
Contact input 8
9
Contact input common