Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example #1:What is the range of possible values for Codabar Coding Enable?
Enter:
cbrena*.
Response:
CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of
values from 0 to 1 (off and on).
Example #2: What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response:
CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example #3: What is the device’s current setting for Codabar Coding Enable?
Enter:
cbrena?.
Response:
CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on.
Example #4: What are the device’s settings for all Codabar selections?
Enter:
cbr?.
Response:
CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Summary of Contents for 4600g
Page 1: ... 4600rp 4600g 4600r 4800i Commercial Retail Industrial Area Imager User s Guide ...
Page 6: ......
Page 16: ...x ...
Page 32: ...1 16 ...
Page 72: ...3 24 ...
Page 80: ...4 8 ...
Page 144: ...7 50 ...
Page 164: ...8 20 ...
Page 178: ...9 14 ...
Page 230: ...14 6 ...
Page 244: ...OCR Programming Chart a e d g c h t l r ...
Page 245: ...OCR Programming Chart T D A O Save Discard ...