3 - 24
Auto Reconnect Mode
Auto Reconnect controls whether or not the scanner automatically begins the relink process when a loss of connection is
detected. When the
Auto Reconnect On
bar code is scanned, the scanner begins the relink process immediately, without
user intervention.
Default = Auto Reconnect On.
Note: If you are connecting to a Bluetooth Interface Module, set Auto Reconnect to Off.
The table below shows the results of the Auto Reconnect On and Off settings:
Maximum Link Attempts
The Maximum Link Attempts setting controls the number of times the scanner tries to form a connection with a base or an
Access Point. During the connection setup process, the scanner transmits in order to search for and connect to a base or
an Access Point. In order to prevent continuous transmissions that could interfere with other users of the ISM band, the
number of attempts to connect is limited by this setting. After the maximum number of attempts is reached, the scanner will
not attempt to reconnect to a base or an Access Point. Pressing the trigger, scanning an Access Point linking bar code, or
placing the scanner in the cradle resets the attempt count and the scanner will again try to link.
Event
Auto Reconnect On
Auto Reconnect Off
Scanner out of range
Relink occurs automatically. If maximum
number of link attempts is unsuccessful,
then the scanner must be relinked by
either pulling the trigger, placing the
scanner in the base, or scanning the
Access Point linking bar code. (See
"Maximum Link Attempts" on page 3-24.)
The scanner is relinked by pulling the
trigger, or scanning the Access Point
linking bar code.
Base or Access point reset
(firmware upgrade or power cycle)
Scanner behaves as if out of range.
No attempt to relink made while base
or Access Point is powered off.
Trigger must be pulled to initiate
relinking.
Scanner power down due to
Power Time-Out Timer setting
(see
Trigger must be pulled, Access Point linking bar code must be scanned, or the
scanner must be placed in the base unit to relink.
(Note: scanner relinks on power up, but powers on due to one of the above
actions.)
Scanner reset due to firmware
upgrade
Relink occurs automatically.
Scanner reset due to battery
change
Relink occurs automatically.
Scanner placed in different base
unit
Relink to new base occurs automatically.
* Auto Reconnect On
Auto Reconnect Off
Summary of Contents for 145*g1D
Page 1: ...Voyager 1450g 1452g Series Area Imaging Scanner User s Guide ...
Page 18: ...1 8 ...
Page 42: ...2 24 ...
Page 70: ...3 28 ...
Page 87: ...4 17 Upright Vertical Bottom to Top Upside Down Vertical Top to Bottom ...
Page 88: ...4 18 ...
Page 102: ...6 10 Data Format 3 ...
Page 154: ...9 4 ...
Page 184: ...11 8 ...
Page 200: ...A 10 ...