Date of Issue: April 2008
9-7
WDP30X
3. Remove the connecting rod and measure the plastigauge.
4. If the clearance exceeds the service limit, replace the
connecting rod and recheck the clearance.
• CAMSHAFT CAM HEIGHT
• CAMSHAFT O.D.
• CAMSHAFT HOLDER I.D.
Standard
Service limit
0.040 ~ 0.063 mm
0.0016 ~ 0.0025 in)
0.12 mm (0.005 in)
Standard
Service limit
IN
27.70 mm (1.090 in)
27.45 mm (1.081 in)
EX
27.75 mm (1.093 in)
27.50 mm (1.083 in)
Standard
Service limit
13.984 mm (0.5506 in)
13.916 mm (0.5479 in)
Standard
Service limit
14.0 mm (0.55 in)
14.048 mm (0.5531 in)
PLASTIGAUGE SCALE
PLASTIGAUGE