7
Rev 06/2019
16.
Insert the corner seal and corner brackets on the left side of
glass F (will have holes for door hinge) attach to panel D & C
with angle brackets and connector bolts. Attach door hinges
and door Panel G.
17.
Put the wood floor grids in the shower tray and benches in the
unit. Attach flexible waterline to outlet on panel A and the
other end to the handheld shower wand. Attach to the
bracket. Note: the hex nut of the water line goes on the panel
outlet.
18.
Attach handle to the door and shelves to panels B and C.
19.
Installing the door gaskets: Two Half-moon gaskets are
installed on the side of the door and the fixed panel where the
hinges are. The gasket that is attached to the fixed panel
should be from the bottom of the base to the top of the glass.
The gasket on the door needs to be just short of touching the
base when the door is opened and closed. The magnetic
gaskets are installed the same way. The two gaskets with the
magnetic strips are installed on the door opening side and the
fixed panel on the other side.
20.
This gasket must go between the magnetic gasket and the
bubble gasket on the hinge side. The magnetic gasket and
bubble gasket must extent down to almost touching the base
top otherwise there could be some leaking.
21.
Steam Cup Connection Diagram
A: Steam outlet
B: Steam line Connector
C: Glass
D: Steam hose
Summary of Contents for M6028/6
Page 11: ...10 Rev 06 2019 SCHEMATIC...