MAINTENANCE & CARE 

Disassembly: 

1. Replacement parts may be available at Lowes or Home Depot. 
2. When replacement parts are not available, please write or call 
Price Pfister Consumer Service. 
3. Always turn off water and release pressure before working on 
your faucet. 

Note: Trim Care 

Cleaning instructions: 

For all Handles and decorative finishes, use only a soft damp cloth 
to clean and shine. Use of polish, detergents, abrasive cleaners, 
organic solvents or acid may cause damage. Use of other than a 
soft damp cloth will nullify the warranty. 
Trim products which contain porcelain or other similar substances 
are not acceptable for public areas or commercial use. Installation 

of said trim is at users’ risk!

 

TROUBLESHOOTING TIPS 

 

Temperature or flow does not remain consistent. 

The cartridge assembly (D) may need cleaning. Shut off water 
supply. Remove handle assembly (A), unscrew retainer sleeve (B) 
and remove flange (C). Remove cartridge assembly (D) and 
inspect cartridge (E) and inlets for debris or sediment and flush 
with water. Reassemble the whole unit and test. If problem persist 
you may need to replace the cartridge. 

Sleeve (B) is too short. 

Extension kid 910-563 is available at a nominal charge for valves 
which have been roughed-in too far back in the wall. The kit 
contains a one-inch stem extension, and a sleeve which is one 
inch longer than the 972-300. 

Dripping from either the tub spout or shower head. 

Clean the cartridge assembly (D). check to ensure the two oval 
O-Rings (F) on the back of the cartridge (E) are in place. 
Reassemble cartridge, stem and bonnet assembly and handle. 
Turn on the water and test. Of the unit still leaks, replace the 
cartridge (E). 

Make sure that both hot and cold-water inlets are turned on. 
Water flow is very low. 

Check the cartridge assembly (D), for debris. Sediment where 
the water enters the shower head (G) can also cause this 
symptom. 

Water starts out hot and becomes cooler as handle is 
rotated counter clockwise. 

This is a potentially hazardous situation and should be corrected 
before using the unit. Check the hot and cold inlet positions (hot-
left, cold-right). If you have a back to back installation, (where hot 
and cold inlets are reversed) refer to valve body instruction sheet 
for back to back installation. 

Water flows from the shower head while filling the tub. 

Check the position of the valve body (J). The letters SHWR 
should be vase into the top and TUB on the bottom. 

Water doesn’t get hot enough.

 

Remove hand (A), sleeve (B) and flange (C) and then refer to 
valve body instruction sheets for adjusting temperature range. 

Water flows from the tub spout while using the shower. 

The seal inside of the diverter mechanism may have become 
dislodged. The spout (H) may need replacement. 

 

CLEANING CARTRIDGE 

If temperature or flow does not remain constant, the cartridge 
assembly (A) must be cleaned. Shut-off water supply. Remove 
trip assembly (not shown). Remove screws (C), backup plate (B) 
and cartridge assembly (A). inspect inlets for sediment and flush 
with water. Inspect O-rings (D & E) for damage. Re-install 
cartridge assembly (A) and backup plate (B) then turn on water 
supply. If the problem persists replace cartridge assembly (A). 

 
CAUTION:

 Do not disassemble cartridge (A). 

Summary of Contents for M6028/6

Page 1: ...rly please follow all instructions provided in this User s Manual Our company reserves the right to change the Manual at any time The manual takes effect the date it s published This manual shall prev...

Page 2: ...NS 5 CONTROLLER FUNCTIONS 8 KEYPAD OPERATION 9 CHANGING THE DEFAULT VALUES 9 CHANGING THE DEFAULT TEMPERATURE 9 BRIEF TROUBLE SHOOTING GUIDE 9 SCHEMATIC 10 PFISTER HANDLE ASSEMBLY 11 TRIM FLANGE ATTAC...

Page 3: ...ight to change specs or features at any time Please check to confirm details 1 866 783 2661 PACKING NOTE 1 When first opening the boxes please make sure everything is in good condition especially if a...

Page 4: ...en wrench SECTION PICTURE OF RUBBER SEAL GLASS Glass A Main Panel Black Glass B Large Back Panel Black Glass C Side Panel Black Glass D Top Black Glass E Front Clear Panel with Black Stripe on Top Sid...

Page 5: ...to connect from the faucet manifold on the unit to the shutoff valves All fixtures and fittings must be checked for tightness as they may have been loosened during transport It is advised to have base...

Page 6: ...panel Connect with screw Note Attach glass shelf brackets to back of panel B before proceeding 5 Install angle brackets to the glass panel C Install the angle bracket to the holes on glass panel C Re...

Page 7: ...of soap or lubricant on the gaskets will help with installation Slide into top right side gasket of panel large back panel B 14 Place glass D top on the top of the unit align connecting holes with gla...

Page 8: ...kets are installed on the side of the door and the fixed panel where the hinges are The gasket that is attached to the fixed panel should be from the bottom of the base to the top of the glass The gas...

Page 9: ...ONTROLLER FUNCTIONS Attention Avoid bending the pins inside the cable connection the control panel and steam generator Make sure the arrows on the male and female ends are lined up as illustrated belo...

Page 10: ...ONLY press the time button 3 the hour will flash 6 Rotate the fly shuttle 7 to the desired hour press the fly shuttle 7 to set the hour The minutes will start to flash 6 rotate the fly shuttle to the...

Page 11: ...10 Rev 06 2019 SCHEMATIC...

Page 12: ...Screw Stem Extender A onto the Valve Stem B Thread the Set Screw C into the Handle and thread it in only three or four turns With valve in CLOSED position place handle D onto the Steam Extender A and...

Page 13: ...e back of the cartridge E are in place Reassemble cartridge stem and bonnet assembly and handle Turn on the water and test Of the unit still leaks replace the cartridge E Make sure that both hot and c...

Page 14: ...discharged as steam USING THE STEAM GENERATOR CLEAN OUT VALVE Shut off the water supply to the unit if you don t when you unscrew the cover water will spray all over Unscrew the cover to the valve Hav...

Page 15: ...assistance call 866 783 2661 WARRANTY INFORMATION REGISTRATION Please visit our website homewardbath com warranty registration Please note serial number ____________________________ Registration must...

Reviews: