4
Rev 06/2019
WATER AND ELECTRICITY INSTALLATION INSTRUCTION FOR ALL MODELS
Water: Two water lines for cold and hot water respectively ½-inch National Pipe Thread (NPT).
Power: Power requirement: Single-phase three-wire 220V power supply.
TECHNICAL INFORMATION
✓
Materials: Acrylic, Aluminum, Tempered Glass
✓
Power Supply: 220V
✓
Dimensions: 59 x 40 x 84 IN*
*Additional space for the steam generator is needed outside of steam room shower dimensions.
ELECTRICAL INFORMATION
✓
220-volt, 30-amp GFCI breaker
✓
1 dedicated 10-2 line for steam (line 1, line 2, and ground)
PLUMBING REQUIREMENTS
✓
The unit is equipped with hot and cold, metal braided ½ inch water supply hose with ½ national pipe thread.
✓
Need to install hot and cold shutoffs with ½ -male national pipe thread (not included).
✓
Supply hoses are to connect from the faucet manifold on the unit to the shutoff valves.
✓
All fixtures and fittings must be checked for tightness as they may have been loosened during transport. It is advised to have
base onsite before preparing drain location. Access panel advised.
✓
Please contact Homeward Bath for special instructions regarding connection of the steam generator drain and steam cup
drain to the main drain.
GENERAL INFORMATION
✓
Additional space for the steam generator is needed.
✓
Units come broken down in panels and are assembled with screws, nuts and bolts on site. This unit assembles from the inside
for convenience.
✓
Note: All shower bases may need to be set in mortar for leveling purposes.
✓
It is advised to have base onsite before preparing drain location
✓
Access panel area recommended.
✓
Note: When assembling, ALL glass panels must be square and plumb.