13
Rev 06/2019
FAUCET FUNCTION AND USAGE
•
Water Diverter handle
o
Turn the diverter handle according to the signs marked on its face.
•
When you use the hand held shower, turn the knob to the hand held shower sign;
•
When you use the massage jets, turn the knob to the back-massage sign.
•
When you use the rainfall shower head, turn the knob to the rainfall shower sign
•
Cold Water and Hot:
o
Turn the faucet to left and right to increase/decrease the water temperature.
CLEANING AND MAINTENANCE
•
Liquid detergents and soft cloth should be used. DO NOT clean with acetone and ammonia detergents on fixtures. Do not use
detergents with formic acid or formaldehyde. Do not use any abrasive cleaners.
•
Mineral deposits/scaling on surface can be cleaned by soft cloth with heated vinegar.
•
After every 30 uses, we suggest you to clean the steam generator.
o
Make a solution mixed with 1.5-1.7 liter of warm water and 5-10 grams of citric acid. Or, use straight white
vinegar. Pour the solution into the steam generator through the cleaning valve on the inside of the shower. Turn
it on after 8 to 10 hours; wait for it to be discharged as steam.
USING THE STEAM GENERATOR CLEAN OUT VALVE
Shut off the water supply to the unit, if you don’t when you unscrew the cover water will spray all over.
Unscrew the cover to the valve,
Have the cleaning solution ready Citric Acid about 2 to 3 cups
Start steam generator
–
(set the temperature to the highest) the water valve will
open and will allow you to pour the cleaning solution into the valve.
The valve will open and close several times to fill the steam generator. Keep filling
the valve, once the tank is full the valve will stop opening and closing, shortly after
steam will start to come out the steam outlet. As the solution is used the valve will
start to open and close again. Let it cycle a few times and keep filling the valve.
After the steam Generator has been running a few minutes, shut off the power AT
THE CIRCUIT BREAKER. If you use the key pad, the steam generator will drain
after a few seconds and the solution will not have had enough time to work.
After 30 minutes or so, replace the cover on the valve, turn on the water supply
and power and start the steam Generator as usual. You can let the unit run for
about 1 minute, shut off the power (at the keypad) and wait about 10 minutes for the solution to drain from the steam generator. After
that, you use the unit as usual.