
9
Rev 06/2019
KEYPAD OPERATION
The blue ring around the fly shuttle indicates the unit is in standby mode and ready for operation (8).
Press the on/off button to start the operation of the generator. (1)
Note - If the Steam Light (9) starts blinking, it means there is no water coming to the generator. Determine the cause and correct.
The unit will display the default time (6) and ambient temperature (5). To find out the default temperature press the temperature
adjustment button (4).
The unit will fill with water and after a few minutes begin to produce steam
Once the unit has been shut off either by the time setting or manually pressing the on/off button (1), the automatic drain function of the
generator will engage after about 20 minutes. If you do not want to wait for the automatic drain to engage, you can override it by
pressing the Light/Manual drain button (2). This will start the drain process immediately.
While the unit is in operation, you would press the Light/Manual Drain (2) button to engage the light feature of the system.
Temperature conversion: C to F or F to C. While the system is in standby mode, press and hold the thermostat button (4) for 2
seconds.
Make sure the unit is running by pressing the on/off button (1)
The default time and temperature will be displayed and the unit will start to fill with water.
1.
TO CHANGE THE TIME FOR THE CURRENT SESSION ONLY
, press the time button (3), the hour will flash (6). Rotate the
fly shuttle (7) to the desired hour, press the fly shuttle (7) to set the hour. The minutes will start to flash (6), rotate the fly
shuttle to the desired minutes, then press the fly shuttle (7) to set the desired time.
2.
TO CHANGE THE TEMPERATURE FOR THE CURRENT SESSION ONLY
, press the temperature button (4) and the
temperature display will begin to flash (5). Rotate the fly shuttle (7) to the desired temperature (5) and press the fly shuttle (7)
to set the temperature. The Steam temperature range is 25 C to 68 C or 78 F to 155 F.
CHANGING THE DEFAULT VALUES
Make sure the unit is running by pressing the on/off button (1)
To change the default time
1.
Press the time button (3) on the keypad. The hour setting will flash (6).
2.
Rotate the fly shuttle (7) to the desired time. Press fly shuttle button (7).
3.
The minutes display will start blinking (6). Rotate the fly shuttle button (7) to the desired minutes.
4.
Press the timer button (3) for a few seconds or until a beep is heard.
5.
New default time is set.
CHANGING THE DEFAULT TEMPERATURE
1.
Press the temperature indicator (4). The display (5) will flash current temperature setting.
2.
Rotate the fly shuttle (7) until the desired temperature is displayed (5).
3.
Press and hold the temperature indicator (4) for a few seconds or until a beep is heard.
4.
The new temperature is set.
BRIEF TROUBLE SHOOTING GUIDE
E1. Water level sensor failure. Check the main cable connection at the steam generator and keypad.
E2. The temperature sensor has shorted out.
E3. The temperature sensor is defective
Summary of Contents for M6028/6
Page 11: ...10 Rev 06 2019 SCHEMATIC...