11
Rev 06/2019
PFISTER HANDLE ASSEMBLY
TRIM FLANGE ATTACHMENT
Position Flange (A) on the Valve (B) with drain hole (C) at the
bottom. Place Protective Washer (D) on the short end of the
reversible Retainer Sleeve (E). Screw Retainer Sleeve (E) onto
threaded section of the Stem and Bonnet (G). Tighten Retainer
Sleeve (E) by hand until Flange (A) is snug to finished wall surface.
If the short end of the Retainer Sleeve (E) is too short, reverse it to
use the longer end.
HANDLE ATTACHMENT
Screw Stem Extender (A) onto the Valve Stem (B). Thread the Set
Screw (C) into the Handle and thread it in only three or four turns.
With valve in CLOSED position, place handle (D) onto the Steam
Extender (A) and tighten the Set Screw (C) by using the Hex
Wrench (E) that is provided.
Note:
Make sure Set Screw (C) is securely tighten to handle (D).
TEMPERATURE ADJUSTMENTS
Adjustment gear (A) is factory-set to prevent stem from reaching
full hot position. To adjust stem rotation: remove adjustment gear
(A). Rotated steam (B) counterclockwise to determine a
maximum desired temperature. Replace gear aligning
adjustment stop (C) to stem tab surface (D) to stem (B) cannot
move beyond adjustment point.
Summary of Contents for M6028/6