Homewardbath M6028/6 Manual Download Page 6

Rev 06/2019 

INSTALLATION INSTRUCTIONS 

Note: Confirm the drain setup.  
 

1.

 

Place shower tray in the corner where it will be permanently 
located. Note: The handing (R/L) of your unit determines 
which side the 5in mounting plate/shelf goes (ie: A right 
handed unit has the mounting plate/shelf on the right side). 

 

2.

 

Determine placement of Steam Generator, water and electric 
supply. 

3.

 

In the parts box is a roll of a foam type tape with one side that 
has an adhesive on it. This should be placed in the bottom 
channels of the base where the glass panels rest. 

4.

 

Install the corner gaskets on left and right sides of the large 
back panel B, then install the angle bracket to the holes on 
glass B (black back panel). Connect with screw. 

Note: Attach 

glass shelf brackets to back of panel B before proceeding.

 

 

5.

 

Install angle brackets to the glass panel (C). Install the angle 
bracket to the holes on glass, panel C. Refer to picture below. 

Note: Attach glass shelf brackets to back of panel C before 
proceeding.

 

 

6.

 

Place glass C into the slot onto the base and insert into the 
corner seal of glass B. Note: Glass B is the large black panel, 
and glass C is a black side panel. Line up the installation 
holes and connect glass B and glass C. 

Note: Use Windex for 

lubricant.

  

 

7.

 

Insert the half-moon shaped rubber seals onto the right side 
(outside facing edge), and top edge of glass A. Note: top 
gasket may be already installed on the panel  

 

8.

 

To install the key pad, feed the control wire thru the hole of 
the panel.  Remove the cover paper at the bottom. To 
achieve good adhesion effect, keep the sticking surface clean 
and dry. 

 

Summary of Contents for M6028/6

Page 1: ...rly please follow all instructions provided in this User s Manual Our company reserves the right to change the Manual at any time The manual takes effect the date it s published This manual shall prev...

Page 2: ...NS 5 CONTROLLER FUNCTIONS 8 KEYPAD OPERATION 9 CHANGING THE DEFAULT VALUES 9 CHANGING THE DEFAULT TEMPERATURE 9 BRIEF TROUBLE SHOOTING GUIDE 9 SCHEMATIC 10 PFISTER HANDLE ASSEMBLY 11 TRIM FLANGE ATTAC...

Page 3: ...ight to change specs or features at any time Please check to confirm details 1 866 783 2661 PACKING NOTE 1 When first opening the boxes please make sure everything is in good condition especially if a...

Page 4: ...en wrench SECTION PICTURE OF RUBBER SEAL GLASS Glass A Main Panel Black Glass B Large Back Panel Black Glass C Side Panel Black Glass D Top Black Glass E Front Clear Panel with Black Stripe on Top Sid...

Page 5: ...to connect from the faucet manifold on the unit to the shutoff valves All fixtures and fittings must be checked for tightness as they may have been loosened during transport It is advised to have base...

Page 6: ...panel Connect with screw Note Attach glass shelf brackets to back of panel B before proceeding 5 Install angle brackets to the glass panel C Install the angle bracket to the holes on glass panel C Re...

Page 7: ...of soap or lubricant on the gaskets will help with installation Slide into top right side gasket of panel large back panel B 14 Place glass D top on the top of the unit align connecting holes with gla...

Page 8: ...kets are installed on the side of the door and the fixed panel where the hinges are The gasket that is attached to the fixed panel should be from the bottom of the base to the top of the glass The gas...

Page 9: ...ONTROLLER FUNCTIONS Attention Avoid bending the pins inside the cable connection the control panel and steam generator Make sure the arrows on the male and female ends are lined up as illustrated belo...

Page 10: ...ONLY press the time button 3 the hour will flash 6 Rotate the fly shuttle 7 to the desired hour press the fly shuttle 7 to set the hour The minutes will start to flash 6 rotate the fly shuttle to the...

Page 11: ...10 Rev 06 2019 SCHEMATIC...

Page 12: ...Screw Stem Extender A onto the Valve Stem B Thread the Set Screw C into the Handle and thread it in only three or four turns With valve in CLOSED position place handle D onto the Steam Extender A and...

Page 13: ...e back of the cartridge E are in place Reassemble cartridge stem and bonnet assembly and handle Turn on the water and test Of the unit still leaks replace the cartridge E Make sure that both hot and c...

Page 14: ...discharged as steam USING THE STEAM GENERATOR CLEAN OUT VALVE Shut off the water supply to the unit if you don t when you unscrew the cover water will spray all over Unscrew the cover to the valve Hav...

Page 15: ...assistance call 866 783 2661 WARRANTY INFORMATION REGISTRATION Please visit our website homewardbath com warranty registration Please note serial number ____________________________ Registration must...

Reviews: