A 5.58 / A 5.58 P
Maintenance as Required
Checking the Air Cleaner System
The filter cartridge must be serviced when the flow resist-
ance of the filter is highest due to the restriction of the ele-
ment.
This is indicated by the sounding of the horn.
-
Switch off the engine.
-
Remove the hood.
-
Open the three air filter cover clips (1).
-
Pull down housing cover.
-
Pull the air filter cartridge (2) out of the housing by
rotating it slightly.
Cleaning:
-
Blow out air filter cartridge from the inside with maxi-
mum 5 bar air pressure.
Replacement:
-
Install a new air filter cartridge.
Clean the air filter housing with a moist cloth before installa-
tion.
The installation of the air filter cartridge is performed in the
reverse order.
1
Bild_114
2
Bild_115