179
1 Micron Cartridge Filter -
Traps smaller particles that may come from the clean water tank and
pass through the charge pump.
10 Micron Bag Filter –
Traps larger particles that may come from the clean water tank and pass
through the charge pump.
100 Micron Debris Bag –
Installed in debris tank on hooks to collect debris and filter water.
Ball Valve –
ON/OFF valves used to control water flow and draining tanks.
Basic Training Course –
5 days of on-site training to operate and maintain the stripe hog unit.
Bilge Box –
box beneath the ultra-high pressure manifold that contains the sump to collect lubrica-
tion and cooling water from the UHP pump.
Bilge Pump –
Pumps or removes the water from the bilge box to the debris tank.
Blast Head –
The shroud and spray bar that deliver high pressure water to the pavement.
Blower –
Pulls airflow through the vacuum system.
Brush Assembly –
Attaches to the bottom of the shroud providing a partial seal between the blast
head and the road surface to reduce the amount of debris and water exiting during water blasting
operations.
Wear Brush Clamps –
Clamps to the shroud to secure the brush and provide adjustment.
Burst Rating –
The PSI at which a component will rupture.
Manual Bypass Valve –
Located on the ultra-high pressure pump and used to manually adjust
pressure.
Cam Lock Connector –
Installed at the end of each vacuum hose fitting to secure the hose.
Castor Plate –
Supports the hog head and prevents the spray bar from touching the ground.
Cavitation –
Occurs when liquid is subjected to rapid changes of pressure that cause the formation
of cavities in the flow of water that can damage equipment.
Charge Pressure –
Pressurized water supply to the UHP pump.
Charge Pressure Gauge –
Digital gauge that displays the charge pressure in PSI.
Charge Pump –
Centrifugal pump that supplies water to the ultra-high pressure pump.
Chassis –
Steel frame that holds the truck body and motor.
Circuit Breaker -
A device for interrupting an electric circuit to prevent excessive current, as that
caused by a short circuit, from damaging components in the circuit or from causing a fire.
Clean Water Level Sensor –
Sensor that reads the level of water in the clean water tank and indi-
cates the information on the PLC.
Clean Water Tank –
Modular tanks located on the rear of the chassis used to store the clean water
supply for the UHP system.
Cutoff Ball Valve –
Located inside the debris tank as a safety feature to stop the flow of vacuum if
the tank becomes full.
Appendix 5:
Glossary of Terms
Water Blasting Terms
Summary of Contents for STRIPE SH7500
Page 1: ...75 H Operations Manual...
Page 2: ......
Page 72: ...72 NOTES...
Page 108: ...108 NOTES...
Page 161: ...161 Section 5 Scheduled Maintenance...
Page 167: ...167 Appendix 2 Tools Spare Parts...
Page 168: ...168 Appendix 2 Tools Spare Parts...
Page 169: ...169 Appendix 3 Daily Report Pre Op Checklist 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 60...
Page 178: ...178 NOTES...
Page 185: ......
Page 186: ......