75
Section 3 - Operation
NOTICE:
WASTEWATER IN THE BLADDER WILL REDUCE CLEAN
WATER TANK CAPACITY. THE WASTEWATER BLADDER
MUST BE EMPTY FOR MAXIMUM CLEAN WATER CAPACITY.
2.
If this is the first time using the water source, flush
for several minutes prior to filling the tank to help
ensure that no debris enters the system.
3.
Connect the fill hose to the water source and flush
hose for several seconds.
4.
Open the water tank fill valve and connect the hose
to the quick connect fill fitting. Secure the hose to
the fitting with the cam-lock levers.
5.
Slowly open the source valve to begin filling the
tank.
6. Open the 4” ball drain valve on the passenger side
of the tank for several seconds to flush out debris
that may have accumulated on the bottom of the
tank, then close the valve.
7.
Monitor the tank sight glass closely during fill
operations and close the source valve just before
the tank is completely filled.
8.
Close the water tank fill valve, release the cam-
locks and disconnect the fill hose from the fitting.
9.
Remove the fill hose from the water source and
drain the hose.
10. Store the hose in a clean, safe location.
CAUTION
OPERATORS MUST ALWAYS MONITOR THE TANK CLOSELY
DURING FILLING OPERATIONS AS THE FLOW OF WATER
FROM A HYDRANT OR OTHER HIGH VOLUME SOURCE CAN
BE FAR GREATER THAN THE FLOW CAPACITY OF TANK AIR
VENT. OVERFILLING THE TANK WILL CAUSE EXCESSIVE
PRESSURE AND DAMAGE THE TANK.
Rear Clean Water Tank Man-Way & Wastewater Bladder
Clean Water Tank Sight Gauge
Summary of Contents for STRIPE SH7500
Page 1: ...75 H Operations Manual...
Page 2: ......
Page 72: ...72 NOTES...
Page 108: ...108 NOTES...
Page 161: ...161 Section 5 Scheduled Maintenance...
Page 167: ...167 Appendix 2 Tools Spare Parts...
Page 168: ...168 Appendix 2 Tools Spare Parts...
Page 169: ...169 Appendix 3 Daily Report Pre Op Checklist 1 877 HOG ROAD WWW STRIPEHOGSUPPORT COM 60...
Page 178: ...178 NOTES...
Page 185: ......
Page 186: ......