Chapter IV Maintenance
Page 4-58
The procedures tend to certify the calibration
of the camera-based wheel alignment prod-
ucts. The aligner will be certified for accu
-
racy using an apparatus consisting of axles,
stands, and spacers, which are themselves
certified annually. All inspection findings re
-
garding the aligner, will be annotated on the
Certificate of Calibration.
The certification frequency can be a cus
-
tomer-defined. The certification will alert the
user at one year intervals to recertify if not
performed earlier. The customer may deter-
mine the calibration and certification intervals
needed and the accuracy to be specified.
When ISO calibration is complete a screen
will appear with the offset values displayed.
These are the values that will be correlated
in the aligner for traceable accuracy.
The certifying technician will follow the on-
screen instructions.