105 (124)
Procedure
1.
Add an
Empty consume template
and select it.
2.
Name the template
Read Barcode Data
.
3.
In the Frame editor, add four
frame field
with the following settings:
Consume frame fields
Frame
fields
Name
Type
Value
Fixed field Maximum
payload
length
Process
data
delimiter
Subnet
delimiter
End
pattern
Variable
data
Barcode
Data
N/A
N/A
Yes, set
here
31 bytes
None
None
0
Constant
Carriage
Return
character
(CR)
Byte (1
byte)
13
Yes, set
here
N/A
N/A
N/A
N/A
Constant
Line Feed
character
(LF)
Byte (1
byte)
10
Yes, set
here
N/A
N/A
N/A
N/A
Anybus
®
Communicator
™
User Manual
SCM-1202-162 1.1 en-US