36 (124)
7.5
General Subnetwork Settings
7.5.1
Communication Serial Protocol
Before You Begin
Before starting the configuration, select the Serial protocol you want to use:
•
Modbus RTU:
Default setting. Use for serial devices that conform to the Modbus
communication specification.
•
Custom Request/Response:
Create your own custom request/response transactions.
The transactions can be based on the Modbus communication specification or fully
customized.
•
Custom Produce/Consume:
Create your own custom produce/consume transactions.
When changing the serial protocol, all settings are reset to default and all added nodes,
transactions, and transaction templates are deleted.
Procedure
On the
Communication
page, Serial protocol:
1.
To choose a
Serial protocol
, select
Modbus RTU
,
Generic Request/Response
or
Custom
Produce/Consume
.
2.
To confirm the selected protocol, click
Change serial protocol
.
Apply configuration
3.
To apply the settings, click
Apply
in the web-interface header, and follow the instructions.
Anybus
®
Communicator
™
User Manual
SCM-1202-162 1.1 en-US