Troubleshooting
13.1
Troubleshooting Collamat 2600
The troubleshooting will proceed along the paperpath. See following
Figure 19
Table 14: Unwinder troubleshooting
SYMPTOMS
DIAGNOSIS
ACTION
Labels peel off at the
dancer roll
Dancer roll diameter is too
small
Change the standard roll
against a roll with enlarged
diameter
Dancer arm is bent and
breaks
Dancer arm materiel is too
weak or too thin (older
Collamat)
Use new dancer arms
(C2600/C6600/C7600)
Flange of the fixed disk
breaks
Material defect, wrong
type of aluminum
Replace flange against
new series flangie
Unwinder blocks
Disk touches the disk-
brake.
Shaft is blocked
Diskbrake does not open
Shift the disk on the
unwindershaft away from
the diskbrake
Lubricate the bearings on
the shaft
Readjust the diskbrake
The torsion spring comes
off the knurled knob
Wrong kind of torsion
spring
Exchange the torsion
spring against an accord-
ing torsion spring
The unwinder tends to fall
off while side labeling
Paper roll too heavy
Mount a separate clamp to
the module rail to stiffen
the unwinder rail
Dancer roll gets shaky
Shaft screw is loose
Fix the screw (use per-
haps Locktite)
Figure 19: Troubleshooting
1
2
3
4