Cabling and setting up
For a trouble free operation of the Collamat 2600 following items must be ob-
served:
•
Trained personnel
•
Ambient temperature
•
Absence of dirt and dust
•
Absence of splashing water
•
Installation and setting up of the installation
•
Installation and setting up of the Collamat 2600
•
Electromagnetic interferences
•
Safety regulations and safety requirements
9.1
Cabling
Electromagnetic interferences can lead to non repeatable and not obvious er-
rors while labelling. Most times misplaced layout of the cabling, RMI and ESD
interferences disturb the labelling. Because of this, the following rules must
be observed for the cabling:
•
Separated mains and signal cables
•
Use shielded cables
•
All units must be grounded
•
Connect only devices which meet the RMI standards
•
Use power filters in interfered environments and interfered mains supplies
9.2
Setting up
The setting up must be done carefully by trained personnel. The following
items must be observed:
•
Visual check of the labeler unit
Are all electrical and mechanical units correctly attached ?
Are all connectors accessible ?
•
Connect the labeler to the mains and switch it on
Is the power switch illuminated ?
•
Turn off the labeler and unplug it
•
Attach the goods scanner signals to the labeler
•
Connect the remaining units to the labeler
•
Connect the labeler to the mains and switch it on
Do the peripheral units work OK ?
•
Thread the paperweb and adjust the label scanner
•
Dispense a label. Is it dispensed correctly ?