5999.505-01C 12.06.2007 WM
2
20
8.2
Goods scanner NPN
8.2.1
Connecting the goods scanner
The goods scanners is connected to the GSC1connector. Figure 17 shows
the connection of the standard HM Collamat AG IR goods scanner:
Figure 18 shows the connection of a NPN-scanner:
Figure 16: NPN-Reflective scanner
Goodscanner
+12V
GSC
GND
NPN
Figure 17: Connection of the CS IR goods scanner
G
N
D
G
S
C
+
1
2
V
G
N
D
L
S
C
1
2
V
T
C
Y
1
2
V
bn
gn
bn
ws
gb
gn
GND
+12V
GND
GSC1
+12V
IR
Figure 18: Connection of a NPN-scanner
G
N
D
G
S
C
+
1
2
V
G
N
D
L
S
C
1
2
V
T
C
Y
1
2
V
GND
GSC1
+12V
NPN