SOFTWARE
HLF Italian Design
164
I.M. HLF 1700 Eng V15-2022
Before pushing
Test
please
follow the procedures below according to the product you
have to set:
•
Solubles Testing: remove the mixing bowls and place an empty container under
the chutes. Then push
Test
.
•
Coffee Testing: remove the coffee group, place an empty cup under the slide.
Then push
Test
.
•
Milk Testing: place an empty cup under the milk funnels. Then push
Test
.
WARNING
For the next step, the technician action is required.
Once
Test
has been pushed and the product has been delivered, weigh it on the scale
(make sure to reset the scale when the empty container is placed on the plate).
Then push
Set
and fill in with data figured out from the scale (expressed in grams).
In this way, the quantity in grams corresponds to 10 seconds of the dispensing of the
selected product.