DAILY MAINTANANCE
I.M. HLF 1700 Eng V15-2022
117
HLF Italian Design
5.3.6.4 Temperature
Push
Temperature
key.
The following screen shot will appear on the touch screen. This function allows to
change the drink process temperature.
The possible operations to do are the following:
•
Boiler Temperature:
to adjust the temperature inside the boiler. Max C°: 100;
min C°: 30.
C° 0: not used.
•
Recovery Minimum Temperature:
if the boiler temperature falls below the set
temperature, the boiler, after the set
Max Recovery Time
, starts to heat.
It is not possible to dispense drinks until the minimum temperature is reached.
Max C°: 80; min C°: 50.
C° 0: not used.
•
Max Recovery Time:
Maximum time after which the boiler starts heating, if the
boiler temperature falls below the set
Recovery Minimum Temperature
.
Max: 30 sec.; min: 1sec.