−32−
4.Basic Settings Group
Adjust the boost's gain or stability for both A and B Modes.
(2)Turn the volume knob and set the Offset A and B value.
When the settings are done, press the volume knob.
・The setting range is between 1‑199% in 1% increments.
・The default setting value is 100%.
・The boost will rise when the set value is increased
and vice versa. This applies to both wastegate
type selections.
(1)Press the volume knob in the Offset A Set Mode or
Offset B Set Mode.
・The digital display (S) will display [ ].
・The EVC will beep and the digital display (L) blinks.
・"SET" will appear in the display.
・The left illustration references Offset A Set Mode.
Set the boost value to be added to the target boost when the Scramble function is triggered.
(2)Turn the volume knob to select the amount of additional
boost for the Scramble function. After the selection,
press the volume knob to set.
・The setting range is between 0‑120 kPa or 0.0‑17.0 PSI
respectively for the unit of measure selected.
・The default setting is 0 kPa or 0 PSI.
(1)Press the volume knob while in the Scramble Boost Set
Mode.
・Digital Display (S) will illuminate [ ].
・"SBC" will be illuminated on the display.
・The EVC will beep and the digital display (L) blinks.
・"SET"will be illuminated on the display.
4.1.
Offset A Set Mode / Offset B Set Mode
4.2.Scramble Boost Set Mode
Set the time duration of the added Scramble boost for when the Scramble is triggered.
(1)Press the volume knob while in the Scramble Time Set Mode.
・The digital display (S) will illuminate [ ]
・"SBC" will be illuminated on the display.
・The EVC will beep and the digital display (L) blinks.
・"SET"will be illuminated on the display.
4.3.Scramble Time Set Mode