Model
Parameter
Unit
SF 21
SF 41
Exhaust flow at the nominal output
g/s
15
33
Exhaust flow at the minimal output
g/s
5
16
CO emission at the nominal output (10% O
2
)
mg/m
3
151
360
CO emission at the minimal output (10% O
2
)
mg/m
3
800
370
CO emission at the nominal output (13% O
2
)
mg/m
3
116
262
CO emission at the minimal output (13% O
2
)
mg/m
3
582
269
Required chimney draught
Pa / mbar
1 ÷ 5 / 0,01 ÷ 0,05
Noise
dB
below 75
Electricity plug-in
1 PEN ~50Hz 230V TN-S
Electric insulation
IP 20
Electric power consumption (fans and
motoreducer)
W
110
155
Ambient temperature
0
C
15 ÷ 40
Humidity
%
10 ÷ 90%
without condensation
Fuel container capacity
dm
3
150
240
470
Ash tray volume
dm
3
7
15
Outlet fan
model
Z-A RH15Z
Z-A RH18Z
Motoreducer
model
ABM 4.5
ABM 7.5
Table 2. Smart Fire boiler specifications
Smart Fire Manual
wer. 05/07/2012/EN/SL V2.0
HKS LAZAR
str.7
Summary of Contents for SF 21
Page 36: ...13 Declarations and licensing Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 36 ...
Page 37: ...Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 37 ...
Page 38: ...Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 38 ...
Page 39: ...Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 39 ...
Page 40: ...Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 40 ...