8 User's operations manual
Please read this manual as well as that of the system controller. Detailed information concerning the
controller setup are to be found in the controller's manual.
8.1 Launch of the boiler operation
Before launching the boiler:
•
Check if the heating system has enough water;
•
Load adequate amount of fuel in the container.
The boiler will start the ignition process once the controller is activated. The process includes
several tasks that conclude with ignition of the fuel in the burner. Then the boiler will switch to
automatic operation. If the ignition process fails (the exhaust temperature does not rise high
enough) three consecutive attempts of ignition will be taken. If the third attempt fails the controller
will display an alarm. This may happen when setup or fuel are not correct. Contact the service if it
happens.
8.2 Boiler's operation
After the boiler switched from the ignition mode to the operation mode, the amount of fuel fed in
and the fan air flow are set. This is why it offers high efficiency within the entire range of output.
Report all disturbances to the service immediately quoting the messages from the display.
Adjust the setup only when you are certain about its meaning and how it will affect the boiler's
operation. Record all alterations in order to facilitate restoration of a previous setup. This will help
the service and call centre consultation.
•
The boiler doses the fuel in regular intervals. The feeding cycle and the length of a
dose are factory set for the nominal, medium and lowest output. However, lower quality fuel
may require adjustments to these parameters. The reasons may be the following: the boiler
does not switch to the preservation mode or floods the burner with excessive amount of
pellets. Consult the controller's manual before adjustment of these parameters. Check quality
of the pellets before adjustments of the setup. In particular, check moisture, hardness and
dust content soaking a sample in water.
•
Factory temperature setup offers proper operation of the system. However,
occasionally necessity to change this parameter may arise. Follow the recommendations
concerning boiler temperature range and the controller's manual.
Smart Fire Manual
wer. 05/07/2012/EN/SL V2.0
HKS LAZAR
str.18
Summary of Contents for SF 21
Page 36: ...13 Declarations and licensing Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 36 ...
Page 37: ...Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 37 ...
Page 38: ...Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 38 ...
Page 39: ...Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 39 ...
Page 40: ...Smart Fire Manual wer 05 07 2012 EN SL V2 0 HKS LAZAR str 40 ...