Do not:
operate the heat pump in the presence of corrosive or explosive gases;
supply the greasy, contaminated or polluted air;
make connection to ventilation ducts containing water vapour.
Device must be installed pursuant to applicable regulations regarding wiring.
Always check that installation is properly earthed.
Heat pump operation follows with refrigerant R290 that is flammable gas.
Any works related to the circuit shall be delivered with tools for this purpose that comply
with applicable standards. For filling with or refrigerant recovery, device shall be
disconnected from power supply. Smoking is not allowed during device operation
Do not use fire sources (e.g. lighter, burner).
Protection zone shall be provided around the device. Protection zone shall be free from windows,
doors, ventilation openings, lighting fixtures, basement entry, hatches, roof windows or discharge
pipes. Protection zone shall not include any adjacent plot or public circulating routes. Protection
zone shall be free from sources of ignition, including power outlets, lighting switches, lamps or
electrical switches.
Product contains refrigerant R290. In case of leakage, the refrigerant shall be collected close to the earth . Always
prevent discharge of refrigerant into building pits, recess or sewage systems. Prevent accumulation of
refrigerant that pose risk related to formation of hazardous, explosive, suffocating or toxic atmosphere.
2. Transport and assembly
2.1.
Delivery
During receipt of delivery always check devices against specification in the order with regard
to any missing parts or damages resulted from transport.
2.2.
Relocation
Heat pump is shipped on pallet and is secured with bolts and nuts that shall be removed before carrying and
placing the device in the position where operation will follow. Heat pump may be carried with forklift truck,
crane or other equipment that offer appropriate lifting capacity and stability.
Max. pump inclination is 30⁰! CAUTION! Risk of injury during device lifting due to heavy weight.
Max. pump inclination is
30°. Any extensive inclination during device operation may
result in device failure within refrigerant circuit.
During shipping max. pump inclination is 30°.
Operation Manual and Guarantee Card v.010