Icing water temperature shall be always over 7ºC
System shall be filled with Propylene glycol solution
When operating HTi 20 heat pump note to ensure surface cooling by programming
refrigerant temperature that is below dew point
Use of condensation sensor is recommended
Use of flow-meter is recommended
5.6.
Connecting to swimming pool
Heat pump connection to swimming pool heating system is possible, however the following issues shall be
taken into account: do not connect device heating circuit directly to swimming pool system. Always heat
exchanger shall be installed and other components required for such installation.
5.7.
Reference hydraulic system
The following diagrams indicate heat pump connection to buffer tank, hot water tank and building heating
system. To ensure heat pump reliable and good operation, always follow the instructions regarding device
connection to hydraulic system.