To connect an external unit and interior system the opening in the wall shall be delivered for pipe and ducts
penetration. Note to adhere to required minimum safety distance and zone. Temperature within air outlet
area is ca. 5°C below ambient temperature, therefore formation of icing is possible at specific weather
conditions. Note to ensure heat pump position where air outlet is not directed towards circulating routes .
Always adhere to required distance from wall, wall openings, windows, basement windows. Note to ensure
condensate discharge to prevent accumulation of moisture on building foundation.
Figure 5. Heat pump position and assembly.
1 – Heat pump; 2 – Condense drain; 3 – Building wall; 4 – Discharge pipe