38
Maintenance and cleaning
Assembly Instructions
Linear Tables HT-L
HTL-01-0-EN-1905-MA
Linear table operations consume lubricant on a continuous basis. The product must be relubricated at regular intervals. Bear
in mind that small quantities of lubricant can exit the lubrication system.
The following factors affect the lubrication intervals:
|
Dust and dirt
|
Operating temperatures
|
Loads
|
Vibration stress
|
Permanently short positioning distances
|
Rotary speeds
During maintenance:
X
Secure the linear table against being switched on without authorisation.
X
Disconnect the power supply of the linear table.
X
Secure the linear table against being switched back on without authorisation.
The cleaning and lubrication intervals must be observed without fail.
Include these maintenance intervals in your maintenance schedule.
NOTE
Inadequate lubrication or the wrong lubricant increases wear and reduces the service life.
NOTE
7.1 Lubrication
The HT-L linear tables include two linear guideways with two blocks each that are initially lubricated prior to delivery. Relu-
brication is introduced through four grease nipples (one for each block) on the side of the carriage.
The lubrication interval depends on the loading, speed, cycle time, and ambient conditions. Recommended lubrication
intervals are listed in Table 7.1.
Damage from wrong lubricant!
Using a wrong lubricant can cause damage to property and pollute the environment.
X
Use the correct lubricant type (grease, oil) as specified in these assembly instructions!
ATTENTION!
Do not connect!
Work in progress
Site:
Removal of shield solely
by:
Size
Block
Lubricant
Relubrication quantity [cm
3
]
HT150L
QE15
G04
0.55
HT200L
QH20
G04
0.70
HT250L
QH25
G04
0.75
Table 7.1
Lubricant quantities for the linear guideway of the linear tables HT-L