Assembly and connection
35
Assembly Instructions
Linear Tables HT-L
HTL-01-0-EN-1905-MA
6.6.2.2 Connecting the distance measuring system and the Hall sensor
Danger of injury!
An incorrectly connected distance measuring system may cause uncontrolled carriage movements which can lead to
injuries or might damage the linear axis.
X
Only qualified personnel may connect the distance measuring system!
ATTENTION!
If the incremental distance measuring system HIWIN-MAGIC is connected according to Table 6.7, the counting direction
results as shown in Fig. 6.25.
Positive direction of movement
Fig. 6.25
Positive direction of movement for linear table HT-L (connection interface shown: option “D”)
Table 6.5
Pin assignment of built-in socket 9-pin
Pin no.
Signal
A
U
B
V
C
W
GND
GND
1
T1+/PTC SNM 120
2
T1–/PTC SNM 120
3
T2+/PT1000
4
T2–/PT1000
Type
Specification
Designation
1)
Pole configuration
Built-in socket
915, E, 15-pin, flange
EEGA204NN00000001000
1
12
11
10
9
8
5
4
3
2
A
B
C
E
7
6
Matching plug
915, 15-pin, P, D = 8.5 – 10.5
ESTA205NN00330003000
1)
Manufacturer: TE Connectivity Industrial GmbH
Table 6.6
Built-in socket 15-pin