34
Assembly and connection
Assembly Instructions
Linear Tables HT-L
HTL-01-0-EN-1905-MA
6.6.2 Connection of motor and internal distance measuring system for linear tables HT-L
The linear motor axes HT-L have an interface for motor and encoder cables. These are located on the side of the carriage (see
Fig. 6.24) and can be quickly and easily connected without tools by the self-locking quick-release fasteners.
Connection of motor:
Built-in socket 9-pin
Connection of positioning
measuring system:
Built-in socket 15-pin
Fig. 6.24
Electrical connection interface of linear motor axis HT-L
Danger of injury!
An incorrectly connected motor may cause uncontrolled carriage movements which can lead to injuries or might damage
the linear axis.
X
Only qualified personnel may connect the motor!
ATTENTION!
6.6.2.1 Connecting the motor
Type
Specification
Designation
1)
Pole configuration
Built-in socket
915, E, 9-pin, flange
EEGA201NN00000500000
A
C
B
E
5
4
3
2
1
Matching plug
915, 9-pin, P, D = 10.5 – 12
ESTA202NN00340500000
1)
Manufacturer: TE Connectivity Industrial GmbH
Table 6.4
Built-in socket 9-pin