MAINTENANCE
7-105
Check Air Conditioner Condenser
--- every 6 months
If condenser (1) is covered with dirt and/or insects, air
conditioner cooling performance will be reduced.
Remove dirt or stain from fins of condenser (1) using tap water.
If the condenser has been severely contaminated, use a soft
brush. Do not use a hard brush, which may damage the fins.
Check Air Conditioner Drive Belt
--- every 6 months
Check the belt for abnormal deflection and damage.
Check drive belt tension by depressing the midpoint shown
with
mark in the illustration with the thumb. Deflection must
be as follows with a depression force of approximately 98 N
(22 lbf).
Deflection : approx. 6 mm (0.24 in)
Belt Tension Adjustment Procedure
1. Loosen lock nut (2) of tension pulley (4).
2. Move tension pulley (4) to adjust belt tension by turning
belt tension adjustment bolt (3).
3. Securely tighten nut (2).
M4GB-07-111
1
3
2
4
MNEK-07-019