MAINTENANCE
7-114
M. Aftertreatment Device
Check and Clean Aftertreatment Device
--- as required
IMPORTANT: Check and clean flammable materials on
the area around the Aftertreatment device.
Do not disassemble the base machine support parts and
sensors.
When the machine is operated in dusty areas, refer to the page
9-1 "Maintenance Under Special Environmental Conditions".
1. Open the right and left side cover.
2. Check exhaust pipe (1) for cracks.
Check the aftertreatment device units for loose or
disconnection.
3. Check the connectors and harnesses of NOx sensors
(2), temperature sensors (3) and dosing module (4) for
abnormality.
4. Close the side cover.
1
2
4
3
MNSC-07-043
MNSC-07-044