MAINTENANCE
7-52
Hose
Interval
(hours)
Check Points
Abnormalities
Remedies
Every 10
hours
Hose covers
Leak (1)
Replace
Hose ends
Leak (2)
Replace
Fittings
Leak (3)
Retighten or replace
hose or O-ring
Every 250
hours
Hose covers
Leak (4)
Replace
Hose ends
Leak (5)
Replace
Hose covers
Exposed reinforcement
(6)
Replace
Hose covers
Blister (7)
Replace
Hose
Bend (8), Collapse (9)
Replace
Hose ends and Fittings Deformation or
Corrosion (10)
Replace
M137-07-008
M115-07-145
M115-07-146
M115-07-147
M115-07-148
M115-07-149
9
10
8
6
7
4
5
3
2
1
2
3
3
2
1
2
3
Fig.1