MAINTENANCE
7-48
Replace Air Breather Element
--- every 2000 hours
d
WARNING: Hydraulic oil becomes hot and pressurized
during operation.
Severe burns may result if skin comes in contact
with escaping hydraulic oil immediately after
operation. Wait for the oil to cool before starting any
maintenance work.
Replace
1. Park the machine following the same procedures as
described on page 7-7 for preparation of inspection/
maintenance work.
2. Before replacing the filter element, be sure to relieve the
air pressure from the hydraulic oil tank by pressing air
bleed valve (1).
3. Rotate cover (3) clockwise approx. 1/4 turns. Remove cap
(2) by rotating it counterclockwise.
4. Rotate cover (3) counterclockwise and remove it.
Remove element (4).
5. Install new element (4). Tighten cover (3) clockwise.
After cover (3) come in contact with the inside element,
tighten the cover by 1/4 turn further.
6. Manually tighten cap (2) clockwise to the end. Hold cap
(2) in position by hand to prevent the cap from turning.
Tighten cover (3) counterclockwise 5 to 10° securely.
7. Take care not to allow water or dust to enter the
clearance (air discharge port) between cover (3) and
body (5).
f
NOTE: Replace the element at the recommended regular
intervals to keep the hydraulic oil clean and to extend the
service life of the hydraulic components.
2
3
4
5
M4GB-07-166
1
MNSC-07-013
Summary of Contents for ZW 120-6
Page 4: ......
Page 10: ...MACHINE NUMBERS 2 MEMO ...
Page 58: ...SAFETY SIGNS S 48 MEMO ...
Page 156: ...BREAK IN 2 2 MEMO ...
Page 206: ...OPERATING MACHINE 5 20 MEMO ...
Page 218: ...TRANSPORTING 6 12 MEMO ...
Page 331: ...MAINTENANCE 7 113 25 Cutting edge mounting bolt Bolt dia in 1 Quantity 7 M4GB 07 116 ...
Page 344: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 4 MEMO ...
Page 348: ...STORAGE 10 4 MEMO ...
Page 354: ...TROUBLESHOOTING 11 6 MEMO ...
Page 356: ...SPECIFICATIONS 12 2 MEMO ...
Page 360: ...13 4 OPTIONAL ATTACHMENTS HYDRAULIC TYPE QUICK COUPLER OPERATION MEMO ...