MAINTENANCE
7-82
M1J1-07-027
M1J1-07-044
1
2
2. Remove the radiator cap. Open drain cocks (1) and (2)
on the radiator and engine block to allow the coolant to
drain completely.
3. Close drain cocks (1) and (2). Fill the radiator with tap
water and a radiator cleaner agent. Start the engine and
run at a speed slightly higher than slow idle; when the
needle of the temperature gauge reaches the green
zone, run the engine for about ten more minutes.
4. Stop the engine and open drain cock (1). Flush out the
cooling system with tap water, until draining water is
clear. This helps remove rust and sediment.
5. Close drain cock (1). Fill the radiator with tap water and
an anti-rust agent or antifreeze at the specified mixing
ratio. When adding coolant, do so slowly to avoid mixing
air bubbles in the system.
6. Run the engine to sufficiently bleed the air from the
cooling system.
7. After adding coolant, operate the engine for several
minutes. Check the coolant level again, and add coolant
if necessary.
M1JB-07-015
1
ZX450LC
-3
ZX450LC
-3
, 650LC
-3
M1J7-07-022
1
ZX650LC
-3
ZX850LC
-3
M17V-07-033
2
ZX850LC
-3
Summary of Contents for ZAXIS 450LC-3
Page 1: ...Serial No 020001 and up Hydraulic Excavator PART NO EM1J3 NA1 2 450LC 3 650LC 3 850LC 3 ...
Page 2: ... ...
Page 4: ......
Page 45: ...SAFETY SIGNS S 33 SS 862 SS 863 SS 859 1 2 3 ...
Page 46: ...SAFETY SIGNS S 34 SS3106039 SS3092349 SS 408 4 5 6 ...
Page 48: ...SAFETY SIGNS S 36 SS 024 SS 710 SS3089713 10 11 12 ...
Page 136: ...OPERATOR S STATION 1 88 MEMO ...
Page 138: ...BREAK IN 2 MEMO ...
Page 150: ...OPERATING THE ENGINE 3 12 MEMO ...
Page 270: ...TRANSPORTING 6 78 MEMO ...
Page 406: ...MAINTENANCE 7 136 M1J1 07 083 33 Retighten air compressor mounting bolts ...
Page 408: ...MAINTENANCE 7 138 MEMO ...
Page 410: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 MEMO ...
Page 438: ...SPECIFICATIONS 12 14 MEMO ...
Page 470: ...OPTIONAL ATTACHMENTS AND DEVICES 13 32 MEMO ...
Page 474: ...INDEX 14 MEMO ...