Trap reference
code
Description
Section
Alert level
Host
report
1
SIM
22
SIM
23
SIM
13
da
4x
xx
A change to an S-VOL was
received from the RCU (An
instruction to delete a pair was
received in the Duplex status.)
Failure
with paired
volumes
SERVICE
No
da
5x
xx
A change to an S-VOL was
received from the RCU (A pair
deletion was completed.)
Failure
with paired
volumes
SERVICE
No
da
6x
xx
A change to an S-VOL was
received from the RCU (An
instruction to delete a pair was
received in the Hold status.)
Failure
with paired
volumes
SERVICE
No
db
0x
xx
Drive port temporary error
Drive error SERVICE
Yes
db
1x
xx
Drive port temporary error
Drive error SERVICE
Yes
db
2x
xx
Drive port temporary error
Drive error SERVICE
Yes
db
3x
xx
Drive port temporary error
Drive error SERVICE
Yes
db
4x
xx
Drive port blockade
Drive error MODERAT
E
Yes
db
5x
xx
Drive port blockade
Drive error MODERAT
E
Yes
db
6x
xx
Drive port blockade
Drive error MODERAT
E
Yes
db
7x
xx
Drive port blockade
Drive error MODERAT
E
Yes
db
8x
xx
LDEV blockade (Effect of Drive
port blockade)
Drive error SERIOUS
Yes
db
9x
xx
LDEV blockade (Effect of Drive
port blockade)
Drive error SERIOUS
Yes
db
ax
xx
LDEV blockade (Effect of Drive
port blockade)
Drive error SERIOUS
Yes
db
bx
xx
LDEV blockade (Effect of Drive
port blockade)
Drive error SERIOUS
Yes
db
cx
xx
Drive Link Rate Abnormality
Drive error SERVICE
Yes
Failure trap reference codes
Chapter 8: SIM codes
Hitachi Alert Notification Guide for VSP5000 Series
80