Trap reference
code
Description
Section
Alert level
Host
report
1
SIM
22
SIM
23
SIM
13
d8
9x
xx
A Delta volume to be used by
the URMF/UR was redefined
Failure
with paired
volumes
SERVICE
Yes
5
d9
0x
xx
A change to an S-VOL was
received from the MCU (From
Simplex to Duplex Pending)
Failure
with paired
volumes
SERVICE
Yes
5
d9
1x
xx
A change to an S-VOL was
received from the MCU (From
Simplex to Duplex)
Failure
with paired
volumes
SERVICE
Yes
5
d9
2x
xx
A change to an S-VOL was
received from the MCU (From
Duplex Pending to Duplex)
Failure
with paired
volumes
SERVICE
Yes
5
d9
3x
xx
A change to an S-VOL was
received from the MCU (From
Duplex Pending to Suspend)
Failure
with paired
volumes
SERVICE
Yes
5
d9
4x
xx
A change to an S-VOL was
received from the MCU (From
Duplex to Suspend)
Failure
with paired
volumes
SERVICE
Yes
5
d9
5x
xx
A change to an S-VOL was
received from the MCU (From
Duplex to Simplex)
Failure
with paired
volumes
SERVICE
Yes
5
d9
6x
xx
A change to an S-VOL was
received from the MCU (From
Duplex Pending to Simplex)
Failure
with paired
volumes
SERVICE
Yes
5
d9
7x
xx
A change to an S-VOL was
received from the MCU (From
Suspend to Simplex)
Failure
with paired
volumes
SERVICE
Yes
5
d9
8x
xx
A change to an S-VOL was
received from the MCU (From
Suspend to Duplex Pending)
Failure
with paired
volumes
SERVICE
Yes
5
d9
9x
xx
A change to an S-VOL was
received from the MCU (HOLD
-> PAIR)
Failure
with paired
volumes
SERVICE
Yes
5
Failure trap reference codes
Chapter 8: SIM codes
Hitachi Alert Notification Guide for VSP5000 Series
78